165
(latest NCVER data)Selecting the wrong machine or misreading transformer test data can lead to poor voltage regulation, overheating and unsafe operation. UEEEL0077 Evaluate and report on the performance of LV machines focuses on evaluating single and three phase LV machines from measured and calculated values, and this unit gives RTOs a practical option for electrotechnology programs, delivered through UEEEL0077 training materials.
Learners develop skills in identifying the correct machine for an application, evaluating performance from measured and calculated values, using open and short circuit test data, determining transformer impedance and voltage regulation, diagnosing problems and reporting recommendations with justification.
Get our UEEEL0077 RTO training materials and avoid building machine evaluation content from the ground up. Purchase RTO materials and use the UEEEL0077 training resources as a framework for calculation and reporting tasks.
Inside the UEEEL0077 RTO training materials is a prepared foundation for evaluating and reporting on the performance of LV machines. Purchase RTO materials to start with UEEEL0077 training resources your team can contextualise.
Check the latest unit requirements on training.gov.au before delivery. Your team should contextualise and validate these UEEEL0077 training materials for its learner cohort, delivery model and selected compliance environment. Use the supplied mapping as a starting point when reviewing your UEEEL0077 materials against the Standards for RTOs.
UEEEL0077 Evaluate and report on the performance of LV machines covers determining the correct operation of single and three phase LV machines and evaluating and reporting on their performance. It addresses machine connections, operation, characteristics and protection, and solutions derived from calculated and measured parameters.
The unit addresses five core areas:
Yes. The content covers percentage resistance, reactance and impedance, voltage regulation using load power factor and conditions for maximum and zero regulation.
Learners need access to single and three phase LV machines and transformers with instruments for open circuit, short circuit, insulation resistance and continuity tests. Evidence is required on at least two separate occasions.
Yes. The editable files let your team add nameplate data, test results and case studies from machines your learners work with.
No. They are developed as compliant learning resources, but your organisation should review and validate them before use.
No. The unlimited student licence covers all enrolled learners, subject to the applicable licence conditions.
By submitting this form, you agree to the TotalVET Training Resources Privacy Policy.
UEEEL0079 Plan and analyse LV electrical apparatus
UEEEL0080 Plan and analyse wiring systems, circuits, control and protection for electrical installations
UEEHA0004 Enter a classified hazardous area to undertake work related to electrical equipment
UEEHA0017 Classify areas where a combustible dust hazard may arise
UEEHA0018 Classify areas where flammable gas or vapour hazards may arise
UEEHA0020 Conduct detailed inspection of electrical installations for hazardous areas