2,295
(latest NCVER data)In food storage and distribution, freezer rooms and low temperature cabinets must hold product safely below freezing; UEERA0052 Install, commission, service and maintain low temperature systems develops the ability to install, commission and keep these systems running. RTOs can add it to refrigeration apprenticeships where learners work on single evaporator, single condensing unit systems, with UEERA0052 training materials structuring the delivery.
Learners develop skills in mounting components, installing pipe work, pressure testing and evacuating systems, conducting vacuum drop tests, charging refrigerant, setting superheat and safety controls, configuring defrost, locating and rectifying faults and carrying out preventative maintenance.
Get our UEERA0052 RTO training materials and avoid building low temperature commissioning and fault content internally. Purchase RTO materials and use the UEERA0052 training resources as a clear framework for practical delivery.
These UEERA0052 training resources provide a prepared foundation for installing, commissioning, servicing and maintaining low temperature systems. Purchase RTO materials to reduce development effort and start with organised UEERA0052 RTO training materials.
Check the latest unit requirements on training.gov.au before delivery. Your team should contextualise and validate these UEERA0052 training materials for its learner cohort, delivery model and selected compliance environment. Use the supplied mapping as a starting point when reviewing your UEERA0052 materials against the Standards for RTOs.
UEERA0052 Install, commission, service and maintain low temperature systems covers installing, commissioning, servicing and maintaining low temperature cabinets and freezer rooms that use a single evaporator and single condensing unit. It applies to refrigeration and air conditioning technicians working on low temperature systems.
The unit addresses five core areas:
Learners need access to a low temperature cabinet or freezer room system that can be installed, commissioned, faulted and maintained. A current Trainee Refrigerant Handling Licence is also required for this unit.
Yes. The content covers electric element and hot gas defrost, including typical initiation and termination settings and time initiated, pressure or temperature terminated controls.
The tasks are structured to collect installation, commissioning, fault-finding and maintenance evidence on more than one occasion. They are developed as compliant learning resources, but your team should confirm that equipment and scenarios suit its cohort.
Yes. The editable files let trainers add manufacturer data, control settings and maintenance schedules for the systems they use.
Yes. Free samples are available so your team can review structure and presentation before you purchase RTO materials.
By submitting this form, you agree to the TotalVET Training Resources Privacy Policy.
UEERA0053 Install, commission, service and maintain medium temperature systems
UEERA0055 Manage refrigeration and air conditioning projects
UEERA0056 Monitor and adjust refrigeration energy management systems
UEERA0058 Plan refrigeration and air conditioning projects
UEERA0059 Prepare and connect refrigerant tubing and fittings
UEERA0061 Produce HVAC/R system design drawings