40
(latest NCVER data)Network operators rely on workers who have completed UETDRDU001 Conduct high voltage testing of underground power cable system to confirm the integrity of underground HV cable systems before they are energised or returned to service. It suits RTOs building electricity supply industry distribution pathways that need practical testing capability, and UETDRDU001 learning materials can be shaped around the test sets used in your delivery.
Learners develop skills in determining testing methods, preparing worksites and test equipment, confirming cables are de-energised, applying insulation resistance, VLF and d.c. withstand methods, interpreting test results and completing permits and work records.
Skip building HV testing content internally and use our UETDRDU001 RTO training materials as a structured base for this technical unit. Purchase RTO materials and give assessors UETDRDU001 training resources prepared for test-based delivery.
This package of UETDRDU001 training resources provides a prepared foundation for high voltage testing of underground cable systems. Purchase RTO materials and support consistent delivery with UETDRDU001 training materials that cover preparation, testing and documentation.
Check the latest unit requirements on training.gov.au before delivery. Your team should contextualise and validate these UETDRDU001 training materials for its learner cohort, delivery model and selected compliance environment. Use the supplied mapping as a starting point when reviewing your UETDRDU001 materials against the Standards for RTOs.
UETDRDU001 Conduct high voltage testing of underground power cable system covers testing underground HV power cable systems in the electricity supply industry using a.c. or d.c. voltage methods to identify defects. It also includes interpreting results to determine the integrity of the cable system.
The unit addresses five core areas:
Learners need access to test sets for at least one of the specified methods, such as insulation resistance, VLF a.c. withstand or d.c. withstand, and must complete at least three cable tests. Your team should confirm equipment and cable samples are available before enrolment.
The Learner Guide and Classroom Activities work through what test readings indicate about insulation, sheath and joint condition, so learners can practise analysing results before assessment.
Yes. The editable files allow your team to add network-specific test sheets, permit processes and acceptance values where contextualisation is permitted.
They are developed as compliant learning resources with current unit requirements in mind, but they are not a guarantee of regulatory approval or audit results. Your organisation should validate them before use.
Any number of enrolled learners at the purchasing organisation can use them under the unlimited student licence, with no per-student fees, subject to the applicable licence conditions.
By submitting this form, you agree to the TotalVET Training Resources Privacy Policy.
UETDRDU002 Inspect underground electrical apparatus
UETDRDU009 Install, test and verify distribution underground cable installations
UETDRDU013 Joint, terminate and maintain high voltage underground polymeric cable
UETDRDU015 Joint, terminate and maintain low voltage underground polymeric cable
UETDRDU016 Lay power cables
UETDRDU017 Locate faults in underground power cables





